-40%

Welding Wire 1 Roll Tri-Mark Hobart Flux core High Strength Lo Alloy .052" 1.4mm

$ 21.12

Availability: 100 in stock
  • Diameter: .052
  • Custom Bundle: No
  • Country/Region of Manufacture: United States
  • Non-Domestic Product: No
  • Roll Weight: 33
  • Brand: Hobart Brothers (TRI-MARK)
  • Modified Item: No
  • MPN: S283815T -- K29
  • Condition: New
  • Welding Wire Material: Flux-Core
  • All returns accepted: ReturnsNotAccepted

    Description

    Ask us for a Freight Shipping Quote
    Unbelievable DEAL!
    33 POUNDS
    You are buying 1 Roll
    Ask about a Super Deal: 3 pallets (72 rolls ea)
    Tri-Mark Wire
    .052" (1.4mm)
    33lbs spool (15kg)
    Item Number: S283815T -- K29
    Material: Steel --
    2% nickel
    GAS SHIELDED FLUX CORED WIRE
    TM - 811N3 offers excellent arc stability and low spatter using CO2.
    These weldability features, combined with low diffusible hydrogen levels and good impact values, make the TM - 811N3 a superior choice for shipbuilding, offshore drilling rigs, HSLA steels, and weathering steels where color match is not required.
    The wire is recommended for single and multiple pass welding in all positions using CO2.
    Product Characteristics:
    • Superior welding characteristics in all positions.
    • 2% nickel weld metal promotes good CVN* impact properties.
    *Charpy V-Notch test or toughness test.
    • Can be used with 100% CO2
    • Capable of being used to weld several HSLA* steels.
    *(
    HSLA steels are also more resistant to rust than most carbon steels because of their lack of   pearlite – the fine layers of ferrite (almost pure iron) and cementite in pearlite [citation needed] HSLA steels usually have densities of around 7800 kg/m3).
    Specifications: (This is military surplus)

    Mil E 24403/2 (made for the military specs.)

    Class Mil 101 TC

    Class Mil 101 TM
    Shielding Gas:
    100% CO2
    50 cfh
    Welding Positions:
    All positions
    Diameters:
    .052”
    Weld Test Parameters:
    TM-811N3 .052” diameter electrode was welded using 100% CO2shielding gas with flow rate of 40 cfh, 200 amps (251 IPM), DCEP, and 25 volts with 3/4” electrical stickout and 250 deg ± 25 deg F interpass temperature.
    A total of five layers were welded, two passes each for Layers 2 through 5, one pass on Layer 1.
    The direction of travel was reversed for each layer.
    Typical Undiluted Weld Metal Chemistry:
    C
    Mn
    Si
    P
    S
    Ni
    100% CO2
    0.04
    0.98
    0.33
    0.016
    0.012
    2.00
    Typical Mechanical Properties:
    100% CO2
    Tensile Strength
    97,900 psi (675 MPa)
    Yield Strength
    89,700 psi (619 MPa)
    Elongation
    22.5%
    CVN @ 60 deg F (51C)
    60 ft•lbs (81 J)
    The above properties were determined with 100% CO2 shielding gas.
    Recommended Operating Parameters:
    The information below was determined by welding performed with 100% CO2 shielding gas at a flow rate of 35 cfh.
    Diameter,
    Arc
    Current
    Approx.
    Deposition
    Electrical Stickout
    Voltage
    DCEP (+)
    Wire Feed Speed
    Rate
    (ES) Position
    (volts)
    (amps
    (in/min
    (lbs/hr
    .052”
    22
    100
    95
    2.4
    1/2” to 3/4”
    29
    300
    420
    to
    Flat and Horizontal
    31
    350
    520
    15.3
    -
    --
    -----
    --
    24
    100
    95
    2.4
    25
    200
    240
    Bold
    — Optimum parameters for welder appeal.
    Notice:
    Actual use of the product may produce varying results due to conditions and welding techniques over which Tri-Mark has no control, including, but not limited to, plate chemistry, weldment design, fabrication methods, electrode size, welding procedure, service requirements, and environment.
    The purchaser is solely
    responsible for determining the suitability of Tri-
    Mark products for the purchaser’s own use.
    Any prior representations shall not be binding.
    Tri-Mark disclaims any warranty of merchantability or fitness for any particular purpose with respect to its products.
    Caution:
    Consumers should be thoroughly familiar with the safety precautions shown on the Warning Label posted on each shipment and in
    American National Standard Z49.1, “Safety in Welding and Cutting,” published by the American Welding Society, 550 NW LeJeune Road, Miami, FL 33126, and OSHA Safety and Health Standards 29 CFR 1910, available from the U.S. Department of Labor, Washington, D.C. 20210
    Ask us for a Freight Shipping Quote
    before
    you buy.
    To get a shipping quote send us your zip code to
    your
    commercial address (with a forklift or a loading dock.  Notify us if this is NOT a commercial address.
    You may use your own shipper or pick it up yourself.  HOWEVER, we can only provide you a 2 hour pickup window.  per hour will be charged after the 2 hour window. ( min beyond the 2 hour window).
    After the purchase, please send us the following information:
    a commercial address (with a forklift or a loading dock)
    your company name
    the name of the person receiving this item
    a cell phone number of the person receiving this item for the truck driver